Application of the Algoclear
Cleaning Process biocide
Cleaning Process biocide
The Algoclear Cleaning Process aims at using just enough biocide to kill the biofilm factored by site conditions.
The amount of ACP biocide will vary with the amount of live organisms to kill. It is therefore sensible to remove moss and loose material before application. A fan jet will foam the mix on impact and give a good visual reference for an even application.
The amount of active ingredient in dry form per m² is the real measure of treatment potency. The dosage can be applied with a weak mix, applied liberally, or a strong one, applied thinly. When the water evaporates the surface concentration will increase in the same proportion.
Area per litre of ACP biocide concentrate | Ground / sports / play surfaces | Artificial grass | Concrete & silicone render | Timber | Glass / GRP & Metals |
---|---|---|---|---|---|
Biological load | Average
Low |
1 to 40: first pass | Saturation | Saturation | Low |
Dilution rate | 1 to 40
1 to 50 |
1 to 60: follow up | 1 to 20 | 1 to 20 | 1 to 40 |
Diluted quantity/litre of concentrate | 40 litres
50 litres |
40 to 60 litres | 20 | 20 | 40 |
Guide application rate of the mix on textured/porous surfaces | 4 to 5m2/litre = 160 to 200m2
4 to 5m2/litre = 200 to 250m2 |
4 m2/litre = 160 to 200m2 |
Porous 2 m2/litre = 40m2 | 3 m2/litre = 60m2 | |
Area for 5 litres of ACP biocide concentrate | 800 to 1000 m2 1000 to 1250 m2 |
800 to 1200 m2 | 200 m2 | 300 m2 | |
Guide application rate of the mix on smooth or non-absorbent surfaces | 6 m2/litre = = 240m2/
6 m2/litre =Â 300m2/ |
Painted or acrylic render 3 m2/litre = 60m2 |
8 m2/litre = 320m2 | ||
Area for 5 litres of ACP biocide concentrate | 1200 m2
1500 m2 |
300 m2 | 1600 m2 |
Area per litre of ACP biocide concentrate | Concrete tiles | Clay tiles | Natural slates | Thatch | Cementitious agricultural sheeting |
---|---|---|---|---|---|
Dilution rate | 1 to 20 | 1 to 20 | 1 to 20 | 1 to 30 | 1 to 20 |
Visual guide | Saturation | Saturation | No excessive dribbling at eaves | Saturation | |
Guide application rate of the mix | 0.8 litre/m2 = 1.2 m2/litre | 0.5 litre/m2 = 2 m2/litre | 0.33 litre/m2 = 3 m2/litre | 2 litre/m2 = 0.5 m2/litre | 0.66 litre/m2 = 1.5 m2/litre |
Area for 5 litres of ACP biocide concentrate | 120 m2 | 200 m2 | 300 m2 | 75 m2 | 150 m2 |
Safety on site: Children and domestic animals are kept out of wet areas. Do not leave small ponding areas flooded with a dilute to dry up : Brush the excess liquid away and let dry.